Email: zjbetter@119pump.com
Tel:+86 15336708022(Gloria) +86 13306708055 (Ivy) +86 13357006058 (Serena) +86 13357022877 (Wendy) +86 17757009882(Kate)
Fax:0086-570-3010238
-
- Diesel engine fire pump maintenance
- 2021.01.19
- 1. The correct maintenance of diesel engine fire pumps, especially preventive maintenance, is the easiest and most economical maintenance, so it is the key to extending the service life and reducing the cost of use. Routine maintenance can be carried out according to the following steps to check the amount of fuel in the fuel tank—observe the amount of fuel in the fuel tank and refill as needed.
-
- Daily maintenance of vertical turbine fire pump
- 2021.01.12
- Daily maintenance method of vertical turbine fire pump: 1. Check the oil level of the fuel injection pump governor If the oil level of the fuel injection pump governor does not reach the prescribed engraved mark, it should be added in time, and the upper limit should not be exceeded.
-
- The working conditions of Vertical turbine fire pumps
- 2021.01.12
- Vertical turbine fire pumps are widely used in water plants, hydropower stations (pumps for maintenance, leakage and drainage, etc.), thermal power plants (pumps for industrial, domestic, and fire fighting, etc.)...
-
- Energy saving tips for self-priming centrifugal pumps
- 2021.01.05
- 1. Install the suction bottom valve at the end of the suction pipe of the self-priming sewage pump. The suction bottom valve is actually a kind of check valve, which ensures that the water flow can only enter the suction pipe from the pool and cannot flow back.
-
- Better Technology Co., Ltd obtained the UL certification of the ISO centrifugal pump
- 2020.12.23
- On December 22, 2020, we obtained the UL certification of the ISO centrifugal pump. UL is the abbreviation of Underwriters Laboratories of the United States.
-
- What aspects must be paid attention to choosing the fire pump?
- 2020.12.22
- 1. The material of fire pumps: the fire pumps sold on the market look similar in appearance, and some products are even made exactly the same, but although the two are exactly the same, they are different in quality. One point can be seen in the later use. A good fire pump has the characteristics of good starting characteristics, strong overload capacity, compact structure, convenient maintenance, simple use, and high degree of automation.
-
- Fuel Tank Installation Precautions
- 2020.12.16
- Fuel Tank Installation Precautions. •Suggest the user to install the oil and water separator on the pipe of supply oil. •In the tank connection, it is strictly forbidden to use ordinary raw materials to bring the seal to prevent the dissolution into the diesel engine, resulting in pipeline blockage.
-
- Diesel Engine Fire Pump Room Cooling and Ventilation
- 2020.12.16
- Safety facilities Fire damper and fire detectors and other equipment. According to the degree of fire hazard of the diesel fire pump room, it is possible to determine the corresponding fire integrity level of the pumping station and the adjacent separation zone.
-
- Features and structure of the single stage fire pump
- 2020.12.11
- Features of single-stage fire pump: 1. The pump is compact in structure, small in size, and beautiful in appearance. Its vertical structure determines the small installation area, and its center of gravity coincides with the center of the pump foot, thus enhancing the pump's operational stability and service life.
-
- Vibration isolation ways of the self-priming fire pump (2)
- 2020.12.10
- 6. The rubber vibration isolation pad is arranged in a single layer, and when the frequency ratio cannot meet the requirements, it can be arranged in multiple layers in series, but the number of vibration isolation pads should not be more than five. The type, number of pieces, area and rubber hardness of each layer of rubber vibration isolation pads arranged in series should be completely consistent.
-
- Vibration isolation ways of the self-priming fire pump (1)
- 2020.12.10
- 1. Vibration isolation components should be arranged symmetrically according to the central axis of the pump unit, and the plane arrangement of rubber vibration...
-
- ZJBetter UL listed fire pump set
- 2020.12.08
- UL-EDJ fire pump set. Configuration : UL pump + UL motor +UL diesel engine + UL control panel +UL valve+ jockey pump other accessory; Flow 200-500 GPM; Rated pressure: 103-224 PSI; Speed: 2950-3550 RPM (50hz or 60hz); Maximum working pressure: 280 PSI;
-
- ZJBetter diesel self-priming fire pump
- 2020.12.03
- ZJBetter diesel self-priming fire pump is an energy saving pump designed with ISO international standard and developed through absorbing and improving the related technical data both at home and abroad and belongs to the self-suction centrifugal pump and uses the mechanical seal of a ceramic ring so as to resist any sandy liquid to go into the sealing face...
-
- ZJBetter small flow electric jockey fire pump set
- 2020.12.02
- ZJBetter small flow electric jockey fire pump set is composed of electric pump, jockey pump, control panel and other accessories, and the pump set is portable to be used for fire fighting and high-rising buildings, and other places. The fire pump also can be as stable-pressure equipment.
-
- pipeline pump failure maintenance
- 2020.11.26
- The each type of equipment need certain maintenance and fault maintenance, which can not only ensure the safety of the equipment, but also guarantee the service life of the equipment. 1. Maintenance of pipeline pump: (1) Scrub all parts to be installed.
-
- Operation notes of vertical single-stage fire pump
- 2020.11.24
- The vertical single-stage fire pump is composed of a motor and a pump. The fire pump and the motor are coaxial. The pump structure includes the pump body, impeller, pump cover, and mechanical seal...
-
- Why the fire pump cannot pump water?
- 2020.11.17
- The fire pump cannot pump water: Some users have measured that although the vertical distance from the water reservoir or water tower to the water surface of the fire pump is slightly less than the head of the fire pump, the water lift is still small or unable to pump water. The reason for fire pumps is often that the pipe is too long, the water pipe has many bends, and the resistance loss of the water flow in the pipe is too large.
-
- ZJBetter ISO Single stage centrifugal pump (end suction pump)
- 2020.11.16
- ISO series single-stage centrifugal pump is a single-stage single-suction centrifugal pump product developed by China Better Technology Co., Ltd. with reference to international similar products using modern fluid mechanics to meet the international standard ISO9908 secondary energy efficiency standard. This product combines the strengths of similar products at home and abroad and is
-
- ZJBetter small fre fighting pump set
- 2020.11.12
- ED (EDJ/EJ/DJ/EEJ) small fre fighting pump set (abbreviated as ED small Fire Fighting package set water supply equipment) refers to the flow less than 100 GPM and A highly integrated mechanical and electrical system consisting of electric centrifugal pump, multi-stage centrifugal pump (pressurized pump group), Diesel Engine Centrifugal pump, pressure limiting protection device (safety valve), valve fittings, control system,
-
- What causes the Low speed of fire pump
- 2020.11.11
- Low speed of fire pump (1) Human factors. Due to the damage of the original electric motor, a considerable part of the users randomly equip the fire pump with another electric motor to drive it. As a result, the flow rate is low, the head is low, or even cannot pump water. (2) The transmission belt is worn. There are many large-scale fire pumps that use belt transmission.
-
- ZJBetter Jockey pump installation instructions
- 2020.11.09
- Pump and Piping installation. Pump should be installed in well-ventilated anti-freezing. pump and motor away from the obstacles of at least 150mm. to ensure the smooth motor cooling.
-
- What factors will affect the efficiency of the water pump?
- 2020.11.06
- The water pump is a device for energy conversion. We all know that there will be energy loss in the energy conversion process. Therefore, high energy loss indicates low efficiency of the equipment. So how to improve the efficiency of the pump? What factors will affect the efficiency of the pump? First, let's understand the three main aspects of pump energy loss.
-
- DIESEL SELF-PRIMING SEWAGE PUMP (IRRIGATION PUMP)
- 2020.11.05
- DIESEL SELF-PRIMING SEWAGE PUMP (IRRIGATION PUMP) ZWC diesel engine self-priming sewage pump (diesel engine irrigation pump), is a diesel-powered pump. The pump has self-priming function, can transport clean water, rain with sediment, etc. It can be widely used in farmland irrigation, flood prevent, emergency rescue and so on.
-
- Precautions during the use of the fire pump and its maintenance
- 2020.11.03
- Precautions during the use of the fire pump and its maintenance: (1) During the operation of the fire pump, the bearing temperature should not exceed 35℃ and the temperature should not exceed 80℃. (2) Add bearing lubricating oil to the bearing body of the fire pump. Observe that the oil level should be at the center line of the oil mark.